1 Phase / 1 Phase On-Line UPS

TEOS 100 UPS SERİES

 

1kVA - 2kVA - 3kVA - 6kVA - 10kVA

General Specifications

• True double conversion
• Increased reliability with microprocessor control
• Input power factor correction
    • Output power factor (PF) 0.9
    • Wide input voltage range
    • Can work as a converter
    • ECO Mode for energy saving (for models with 1-3 kVA only)
    • Compatibility with the generator
    • Adjustable battery number (only for 6-10 kVA models)
    • Adjustable charge current (1A ~ 6A) via LCD or software (only for 6 / 10kVA)
    • Emergency shutdown (EPO) is only available for 6/10 kVA
    • User friendly front panel

Technical Specifications

Power

(kVA)

1
2
3
6
10
INPUT

Voltage

Range

60-150VAC / 120-300 VAC

(%50 load) 90-140 VAC /

180-280 VAC (%100 load)

Freq.

Range

40-70Hz

Power

Factor

≥ 0.99 @ Nominal

Voltage

OUTPUT Voltage

100/110/115/120/127VAC 200/208/220/230/240VAC

Voltage

Tole.

±%1

Freq.
50 / 60 Hz

Freq.

range

± %0,1 (synchronous),

±%1 (network sync)

THDv

 %2 (Lineer load), 

 %5(Nonlineer load)

Peak

Coeff.

(Crest Factor) 3:1
EFFIC. Online Up to 92%
GEN. Tech.

Online-double conversion,

PFC

Control Microprocessor, SPWM
Comm. SNMP(optional), RS232

Remote

Monitor.

SNMPView, UPSilon,

Remote Monitoring

panel(optional)

Dry

Contact

Battery mod,

Battery Low

Battery

Start

(Cold Start) Standard

AMBIAN.

Relative humidity

% 0-95

(without condensation)

HEIGHT
2000 m

Noise

< 45 dB (A)
UPS
CAB.

Dimens.

(GxDxY) (mm)

145x

282x

220

145x

397x

220

190x

421x

318

190x

369x

688

190

442

688

BATT.

Internal Battery

Number

of

2
4
6
20 20
Battery Type
12V-9(Ah)

 

Document

  • |Catalog|(PDF)
  • 3 Phase / 1 Phase On-Line UPS

    200 UPS SERİES

    3/1 Uninterruptible Power Supplies

    6kVA - 7,5kVA - 10kVA - 15kVA - 20kVA - 30kVA - 40kVA

    General Specifications • Up to 90% efficiency
    • Galvanic insulation transformer at the output of the inverter
    • Parallel operation feature
    • Static by-pass feature (uninterrupted transmission to load network)
    • Custom production input / output values according to need
    • LCD panel providing detailed information on load status, battery status and UPS
    • 64 or 128 saved event memories
    • RS232 and dry contact output
    • T-MON remote monitoring and management software
    • SNMP, MODBUS compatible communication option
    • Multiple server shutdown module (optional)
    • Production with CE, TSE, ISO9001 and ISO14001 quality assurance system
    • 2-year system warranty and 10-year spare parts warranty guarantee • experienced technical service and customer support services throughout Turkey

    Technical Specifications

    Power

    (kVA)

    10
    15
    20
    30
    40
    INPUT

    Voltage

    Range

    220/380 VAC (230/400 VAC)

    3F + N + Ground ± %15

    Freq.

    Range

    50Hz. / 60Hz. ± %5
    OUTPUT Voltage

    220/230 VAC P + N

    Voltage

    Tole.

    ±%1

    Freq.
    50 / 60 Hz

    Freq.

    Range

    ± %0,2 (synchronous),

    ±%2 (network sync)

    THDv

     %3 (Lineer load), 

     %5(Nonlineer load)

    Peak

    Coeff.

    (Crest Factor) 3:1
    EFFICI. Online %86-90
    GEN. Tech.

    Online-double

    conversion, PFC

    Control Mikroprossesor, SPWM
    Commun. SNMP(optional), RS232

    Remote

    Monitor.

    SNMPView, UPSilon,

    Remote Monitoring Panel

    (optional)

    Dry

    Contact

    Battery mod, Battery low

    Battery Start

    (Cold Start) Standard

    AMBIAN.

    Relative humidity

    % 0-95

    (without condensation)

    Height
    2000 m

    Noise

    < 45 dB (A)
    UPS
    CAB.

    Dimens.

    (GxDxY) (mm)

    265x

    740x

    950

    575x

    820x

    1390

    BATT.

    İnternal Battery

    Number

    20 / 30
    Battery Type
    Dry type without maintenance

    Document

  • |Catalog|(PDF)
  • 3 Phase / 3 Phase On-Line UPS

    DS|POWER H UPS SERİES

    3/3 Uninterruptible Power Supplies

    30kVA - 400kVA

    General Specifications

    • Transformerless UPS technology
    • 3 Level topology
    • Low current harmonic distortion in input
    • High input power factor
    • High efficiency up to 95%
    • Cold start feature
    • Static and maintenance bypass switch
    • Output short-circuit and overload protection
    • External REPO input
    • 512 event recording (512 events, 45000 alarms)
    • Time and calendar
    • Automatic battery test, remaining battery time indication
    • Heat compensated charging system
    • 2 RS232 serial ports and 12 dry contact outputs
    • Modular structure controlled by 3 DSPs
    • Optional SNMP and MODBUS adapters
    • Optional graphic panel
    • Optional usb memory
    • 2 Year warranty
    • 10 year spare parts support
    • Manufactured according to EC EN62040 directive
    • Fully digital structure
    • Small footprint
    • Eco mode operation (optional)
    • Less electronic components
    • Output current limitation
    • Advanced control at entrance
    • Selectable input / output voltage / frequency range
    • Split by-pass input (second input)
    • Output DC leakage protection
    • Separate DSP for inverter control
    • Separate DSP for PFC
    • 3-level battery protection
    • High charge current capacity
    • Charge / discharge current indication
    • Advanced remote control features

    Technical Specifications

    Power

    (kVA)

    30

    40

    60
    80
    100
    INPUT

    Voltage

    Range

    380/400 VAC 3F + N + T

    ± %20 (%100 load)/-%40

    (%70 load)

    Freq.

    Range

    50Hz. / 60Hz. ± %5
    OUTPUT Voltage

    380/400 VAC 3F + N

    ,± %1

    (optional 415 VAC )

    Freq.

    50 / 60 Hz

    THDv

    < %3 ( %100 Lineer load)

    Peak

    Coeff.

    (Crest Factor) 3:1
    GENERAL Tech.

    Online-double conversion,

    PFC

    Control Microprocessor, SPWM
    Comm. SNMP(optional), RS232

    Remote

    Monitor.

    SNMP manager and

    web browser

    power management

    Soft.

     

    T-Mon Admin Multi UPS

    monitoring

    10-50-100-200 user ,

    T-Mon Server

    50-100-200 user

    AMBIANCE

    Relative

    humidity

    % 0-95 (without condensation)
    Height
    2000 m

    Noise

    < 45 dB (A)
    UPS
    CABINED

    Dimens.

    (GxDxY)

    (mm)

    400x

    815x

    1040

    515x855

    x1440

    BATTERY

    İnternal

    Battery

    Number

    2x30 (±30) : 60 pieces

    Battery

    Type

    Dry type without maintenance

    Power

    (kVA)

    160

    200

    250
    300
    400
    INPUT

    Voltage

    Range

    380/400 VAC 3F + N + T

    ± %20 (%100 load)/-%40

    (%70 load)

    Freq.

    Range

    50Hz. / 60Hz. ± %5
    ÇIKIŞ Voltage

    380/400 VAC 3F + N ,

    ± %1 (optional 415 VAC )

    Freq.

    50 / 60 Hz

    THDv

    < %3 ( %100 lineer load)

    Peak Coeff.
    (Crest Factor) 3:1
    GENERAL Tech.

    Online-double conversion,

    PFC

    Control Microprocessor, SPWM
    Comm. SNMP(optional), RS232

    Remote

    Monitor.

    SNMP manager and web

    browser

    power management

    Soft.

     

    T-Mon Admin Multi UPS

    monitoring

    10-50-100-200 user ,

    T-Mon Server

    50-100-200 user

    AMBIANCE

    Relative

    Humid.

    % 0-95

    ( without condensation)

    Height
    2000 m

    Noise

    < 45 dB (A)
    UPS
    CABINED

    Dimen.

    (GxDxY) (mm)

    515x

    855x

    1440

    880x775

    x1900

    1250

    775x

    1900

    BATTERY

    İnternal

    Battery

    Number

    2x30 (±30) : 60 pieces
    Battery Type
    Dry Type without Maintenance

    Document

  • |Catalog|(PDF)